Form 43206000
Sept 2011
INSTALLATION AND OPERATION INSTRUCTIONS
OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly read and
understood before installing, operating or servicing this heater.
RSTP SERIES
INFRARED RADIANT TUBE HEATER
Single Stage Pull Through System (Negative Pressure)
Models:
RSTP15C
RSTP17C
!
INSTALLER
:
owner when you leave the job site.
▲WARNING: Improper installation, adjustment, alteration, service, or maintenance can
cause property damage, injury or death. Read the installation, operation and maintenance
instructions thoroughly before installing or servicing this equipment.
IF YOU SMELL GAS: FOR YOUR SAFETY
FOR YOUR SAFETYFOR YOUR SAFETY
FOR YOUR SAFETY
!
!!
!
DO NOT
DO NOTDO NOT
DO NOT try to light any appliance.
!
!!
! DO NOT
DO NOTDO NOT
DO NOT touch any electrical switch; DO NOT
DO NOTDO NOT
DO NOT use any
telephone in your building.
!
!!
! IMMEDIATELY
IMMEDIATELYIMMEDIATELY
IMMEDIATELY call your gas supplier from a neighbor's
telephone. Follow the gas supplier's instructions. If you
cannot reach your gas supplier, call the fire department.
DO NOT
DO NOT DO NOT
DO NOT store or use gasoline or other
store or use gasoline or other store or use gasoline or other
store or use gasoline or other
flammable vapors and liquids in the vicinity of
flammable vapors and liquids in the vicinity of flammable vapors and liquids in the vicinity of
flammable vapors and liquids in the vicinity of
this or any other appliance.
this or any other appliance.this or any other appliance.
this or any other appliance.
!IMPORTANT:
!IMPORTANT:!IMPORTANT:
!IMPORTANT:
SAVE THIS MANUAL FOR FUTURE REFERENCE.
SAVE THIS MANUAL FOR FUTURE REFERENCE.SAVE THIS MANUAL FOR FUTURE REFERENCE.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
SPACE
SPACESPACE
SPACE-
--
-RAY
RAYRAY
RAY
Post Office Box 36485 (28236) • 305 Doggett Street (28203) • Charlotte, North Carolina
Phone (704) 372-6391 • Fax (704) 332-5843 • www.spaceray.com • email: info@spaceray.com
Page view 0
1 2 3 4 5 6 ... 38 39

Summary of Contents

Page 1 - INFRARED RADIANT TUBE HEATER

Form 43206000 Sept 2011 INSTALLATION AND OPERATION INSTRUCTIONS OWNER / INSTALLER: For your safety this manual must be carefully and thoroughly

Page 2 - SECTION DESCRIPTION PAGE

Form 43206000 Sept 2011 -9- d.EyeboltTurnbuckle*MinimumNo. 2 Chain*Eyeboltc.ThreadedRodTurnbuckleEyeboltb.3/16 x 1 wideFlat BarMinimumNo. 2 Chain*a

Page 3 - 3.0) GENERAL INFORMATION

Form 43206000 -10- Sept 2011 10.0) HEATER ASSEMBLY Sheet metal parts, particularly reflectors and vent have sharpedges. Always use gloves when handl

Page 4 - Sept 2011 -3

Form 43206000 Sept 2011 -11- 2. Install the suspension chains (according to Section 7.0) using proper suspension method (see Section 9.0). chains fo

Page 5 - -4- Sept 2011

Form 43206000 -12- Sept 2011 NOTE:NOTE:NOTE:NOTE: EXHAUST HOODS ANDEXHAUST HOODS ANDEXHAUST HOODS ANDEXHAUST HOODS AND INLET AIR HOODS

Page 6 - 6.1) ACCESSORY PACKAGES

Form 43206000 Sept 2011 -13- 11.0) GAS CONNECTIONS AND REGULATIONS Tighten flexible gas hose and components securely.Flexible metal gas hoses must b

Page 7 - 7.0) DIMENSIONS

Form 43206000 -14- Sept 2011 KEY DIMENSIONS AND COMPONENTS OF THE GAS CONNECTIONSEND VIEWGas Pressure= 2 PSIGGas SupplyPipingSediment Trap(Drip Leg)*

Page 8 - Sept 2011 -7

Form 43206000 Sept 2011 -15- 12.0) INSTRUCTIONS FOR PRESSURE TEST GAUGE CONNECTION Failure to do so may result in death, serious injury or propertyd

Page 9 - SUSPENSION HAZARD

Form 43206000 -16- Sept 2011 13.0) ELECTRICAL CONNECTIONS Failure to do so may result in death or serious injury.This appliance must be connected to

Page 10 - Figure 1 Figure 2

Form 43206000 Sept 2011 -17- SCHEMATICSCHEMATICSCHEMATICSCHEMATIC WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM WIRING DIAGRAM ———— Direct

Page 11 - 10.0) HEATER ASSEMBLY

Form 43206000 -18- Sept 2011 C.C.C.C. LOWLOWLOWLOW VOLTAGE (VOLTAGE (VOLTAGE (VOLTAGE (24242424V) THERMOSTAT CONNECTIONS V) THERMOSTAT CONNEC

Page 12 - Side View

Form 43206000 Sept 2011 -1- TABLE OF CONTENTS SECTION DESCRIPTION PAGE 1.0) Safety ...

Page 13 - Figure 5

Form 43206000 Sept 2011 -19- 14.0) VENTING Failure to do so may result in death, serious injury, property damage or illnessfrom Carbon Monoxide pois

Page 14 - Sept 2011 -13

Form 43206000 -20- Sept 2011 Total VentHeight5 ft (152cm)minimum6 DiameterVent ConnectorTotal VentHeight1/4(6mm)per ft riseLateralSingle Heater Ven

Page 15 - US ONLY:

Form 43206000 Sept 2011 -21- MULTIPLE HEATER VENTING (CONNECTIONS INTO A COMMON VENT OR MANIFOLD)MULTIPLE HEATER VENTING (CONNECTIONS INTO

Page 16 - Sept 2011 -15

Form 43206000 -22- Sept 2011 Multiple Heater Horizontal Venting Arrangement 6 diametersingle wall ventPlan ViewVent Cap2 (5cm)ClearanceThimble6

Page 17 - ELECTRIC SHOCK HAZARD

Form 43206000 Sept 2011 -23- B.B.B.B. INDIRECT VENTING (UNVENTED HEINDIRECT VENTING (UNVENTED HEINDIRECT VENTING (UNVENTED HEINDIRECT VENTI

Page 18 - Sept 2011 -17

Form 43206000 -24- Sept 2011 Flue vent terminationmust be 1 ft. (30cm)higher than combustionair inlet capPerforated Cover(Remove)Control BoxThe combu

Page 19 - -18- Sept 2011

Form 43206000 Sept 2011 -25- To bring outside combustion air to the heater, you will need to order the RSTP Fresh Air Kit (Part #427820RSTP Fresh Air

Page 20 - CARBON MONOXIDE HAZARD

Form 43206000 -26- Sept 2011 16.0) LIGHTING AND SHUTDOWN INSTRUCTIONS Failure to do so may result in death, serious injury or propertydamage.The acc

Page 21 - -20- Sept 2011

Form 43206000 Sept 2011 -27- 18.0) CONTROL COMPONENT LOCATION 1 Cabinet Assembly2 Air Inlet Plate3 Access Panel4 Sight Glass5 Flame Sensor6 Ignition

Page 22 - Sept 2011 -21

Form 43206000 -28- Sept 2011 19.0) CLEANING AND ANNUAL MAINTENANCE ELECTRIC SHOCK & EXPLOSION HAZARDDisconnect electrical power and gas supply b

Page 23 - Plan View

Form 43206000 -2- Sept 2011 1.0) SAFETY This heater is a self-contained infrared radiant tube heater. Safety information required during installat

Page 24 - 15.0) AIR FOR COMBUSTION

Form 43206000 Sept 2011 -29- 20.0) TROUBLESHOOTING GUIDE Turn on line voltageand thermostat. Doesthe green monitoringlight come on in thecontrol ca

Page 25 - -24- Sept 2011

Form 43206000 -30- Sept 2011 30 seconds afterstartup, does theamber monitoring lightcome on in the controlcabinet?YesNowhile the amber lightis on

Page 26 - Side Installation

Form 43206000 Sept 2011 -31- Call for heat ends andthe heater shuts off?YesNoTroubleshooting ends.Thermostat is notworking properly.Replace it i

Page 27 - 17.0) SEQUENCE OF OPERATION

Form 43206000 -32- Sept 2011 21.0) REPLACING PARTS ELECTRIC SHOCK & EXPLOSION HAZARDDisconnect electrical power and gas supply beforeservicing.F

Page 28 - Sept 2011 -27

Form 43206000 Sept 2011 -33- 21.2) REMOVING MAIN BURNER AND GAS VALVE 345612 1. Disconnect electrical supply and gas connection from control box.

Page 29 - -28- Sept 2011

Form 43206000 -34- Sept 2011 21.4) IGNITION SYSTEM CHECKS TO CHECK TO CHECK TO CHECK TO CHECK IGNITION CABLEIGNITION CABLEIGNITION CABLEIGNITION CAB

Page 30 - 20.0) TROUBLESHOOTING GUIDE

Form 43206000 Sept 2011 -35- VALVEVALVE(GND)25V (GND)25VXModuleMultipurposeMeterRed (+)Black (-)FLAME SENSOR CURRENT CHECK- use microamp scale - 2

Page 31 - -30- Sept 2011

Form 43206000 -36- Sept 2011 23.0) REPLACEMENT PARTS GUIDE CONTROL COMPONENTSCONTROL COMPONENTSCONTROL COMPONENTSCONTROL COMPONENTS Item No.Item

Page 32 - Sept 2011 -31

Form 43206000 Sept 2011 -37- CONTROL COMPONENTSCONTROL COMPONENTSCONTROL COMPONENTSCONTROL COMPONENTS Item No.Item No.Item No.Item No. Part No.

Page 33 - 21.0) REPLACING PARTS

Form 43206000 -38- Sept 2011 BODYBODYBODYBODY COMPONENTSCOMPONENTSCOMPONENTSCOMPONENTS Item No.Item No.Item No.Item No. Part No.Part No.Par

Page 34 - Sept 2011 -33

Form 43206000 Sept 2011 -3- The heater, when installed in aircraft hangars and public garages, must be installed in accordance with AN

Page 35 - -34- Sept 2011

Form 43206000 -4- Sept 2011 4.0) MINIMUM CLEARANCES TO COMBUSTIBLES Failure to do so may result in death, serious injury orproperty damage.Combustib

Page 36 - 22.0) INSTALLATION DATA

Form 43206000 Sept 2011 -5- 5.0) SPECIFICATIONS Model No.Model No.Model No.Model No. Btu/hrBtu/hrBtu/hrBtu/hr InInInInputputputput Orifice

Page 37 - -36- Sept 2011

Form 43206000 -6- Sept 2011 7.0) DIMENSIONS Top ViewBottom View18161-5/16exhaust outletperforatedpaneltube exchangerSide View36109-1/215-13/1

Page 38 - Sept 2011 -37

Form 43206000 Sept 2011 -7- 8.0) HEATER ASSEMBLY OVERVIEW 109-1/2suspension chain andturnbuckle rated @230lbsS hooks rated @ 115 lbslong axis of

Page 39 - -38- Sept 2011

Form 43206000 -8- Sept 2011 9.0) TYPICAL SUSPENSION METHODS All materials used to suspend the heater must have a minimum working loadof 115 lbs. All